<5. Parameter Summary>
5-5
IM 01C25T03-01E
No. Parameter name Item
*1
R/W
Content Default value
Applicable
model
Upload
data
F P L
M22 GASKET MATL Gasket material W
M23 PRO CON MATL Flange material W
M24 D-VENT MATL Vent plug material W
M25 PRO CON TYPE Process connection type W
M26 RS ISOL MATL Remote seal material W
M27 PRO CON SIZE Flange size W
M28 NUM RS Number of remote seal W
M29 RS FILL FLUID Fill uid of remote seal W
M30 RS TYPE Remote seal type W
M50 MS CODE 1 Model and sufx code 1 W
M51 MS CODE 2 Model and sufx code 2 W
M52 MS CODE 3 Model and sufx code 3 W
M53 MS CODE 4 Model and sufx code 4 W
M54 MS CODE 5 Model and sufx code 5 W
M55 MS CODE 6 Model and sufx code 6 W
M60 SELF CHECK Self-diagnostics R See A60
P Record History of errors
P10 ERROR REC 1 Last error W See A60 GOOD
P12 ERROR REC 2 Second recent error W See A60 GOOD
P14 ERROR REC 3 Third recent error W See A60 GOOD
P16 ERROR REC 4 Forth recent error W See A60 GOOD
P60 SELF CHECK Self-diagnostics R See A60
T CHARACTERIZR Signal characterizer setting
T10 S. C. ENABLE Signal characterizer permission W INHIBIT or ENABLE INHIBIT
T11 NUM OF POINT Number of coordinates W 0 to 9 0
T20 X START (FIX) Start point of X R 0.00%
T21 Y START (FIX) Start point of Y R 0.00%
T22 X1 Coordinate 1 of X W 0.00 to 100.00% 10.00
T23 Y1 Coordinate 1 of Y W 0.00 to 100.00% 10.00
T24 X2 Coordinate 2 of X W 0.00 to 100.00% 20.00
T25 Y2 Coordinate 2 of Y W 0.00 to 100.00% 20.00
T26 X3 Coordinate 3 of X W 0.00 to 100.00% 30.00
T27 Y3 Coordinate 3 of Y W 0.00 to 100.00% 30.00
T28 X4 Coordinate 4 of X W 0.00 to 100.00% 40.00
T29 Y4 Coordinate 4 of Y W 0.00 to 100.00% 40.00
T30 X5 Coordinate 5 of X W 0.00 to 100.00% 50.00
T31 Y5 Coordinate 5 of Y W 0.00 to 100.00% 50.00
T32 X6 Coordinate 6 of X W 0.00 to 100.00% 60.00
T33 Y6 Coordinate 6 of Y W 0.00 to 100.00% 60.00
T34 X7 Coordinate 7 of X W 0.00 to 100.00% 70.00
T35 Y7 Coordinate 7 of Y W 0.00 to 100.00% 70.00
T36 X8 Coordinate 8 of X W 0.00 to 100.00% 80.00
T37 Y8 Coordinate 8 of Y W 0.00 to 100.00% 80.00
T38 X9 Coordinate 9 of X W 0.00 to 100.00% 90.00
T39 Y9 Coordinate 9 of Y W 0.00 to 100.00% 90.00
T40 X END (FIX) End point of X R 100.00%
T41 Y END (FIX) End point of Y R 100.00%
T60 SELF CHECK Self-diagnostics R See A60
*1: R/W: R = Read only, W = Read & Write
*2: The default value shows MWP (Maximum working pressure) of the capsule.
Since the working pressure limit varies according to the Model, refer to the General Specications section in each user’s manual.