User’s
Manual
Yokogawa Electric Corporation
AXFA14G/C
Magnetic Flowmeter Remote Converter
[
Hardware Edition/Software Edition
]
AXF
Magnetic Flowmeter
Integral Flowmeter
[
Software Edition
]
Aug. 30, 2013
Please use the attached sheets for the pages listed below in IM 01E20C02-01E (10th).
Manual Change No. 13-008-E
Page and Item
Page 1-2, 1-3
1.1 Using the Magnetic Flowmeter Safety
Page 1-4, 1-5, 1-6
1.3 Combination Remote Flowtubes
1.4 ATEX Documentation
Page 4-1
4.1 Wiring Precautions
Page 4-2, 4-3, 4-4
4.2 Cables
4.3 Wiring Ports
4.4 Wiring Connections
Page 4-5
4.4.3 Precautions for Wiring of Power Supply
Cables
Page 4-6
4.4.4 DC Power Connection
Page 4-7
Figure 4.4.7, 4 to 20 mA DC Output Connection
Page 4-8
Figure 4.4.9, Active Pulse Output Connection
(Optional code EM)
Page 4-9
4.4.8 Installing the cover
Page 11-3
Withstand Voltage
Page 11-4
Safety Requirement Standards
Page 12-3
12.3 CSA
Contents of Correction
Added the warning notes in (1) installation, (3) Operation,
and (4) Maintenance.
Changed the page number.
Changed the page number.
Added the important note on “wiring”.
Changed the page number.
Changed the page number.
Changed the page number.
Changed the numbers of “IEC” in warning note.
Changed the page number.
Changed the value of maximum load resistance.
Changed the figure.
Changed the page number.
Changed the values of the withstand voltage.
Added the number of “EN” standard.
Changed the number of Applicable Standard
in (1) Technical Data.
Vista de página 0
1 2 3 4 5 6 ... 17 18

Resumo do Conteúdo

Página 1 - Aug. 30, 2013

User’sManualYokogawa Electric CorporationAXFA14G/CMagnetic Flowmeter Remote Converter[Hardware Edition/Software Edition]AXFMagnetic FlowmeterIntegral

Página 2 - Flowmeter Safely

IM 01E20C02-01E4-44. WIRINGFor working on the electric wire tubes or the flexibletubes (PF1/2), remove the waterproof gland and attachthem directly t

Página 3 - 1.2 Warranty

IM 01E20C02-01E4-54. WIRING4.4.2 Terminal ConfigurationWhen the cover is removed, the connection terminalswill be visible. The terminal configuration

Página 4 - Flowtubes

IM 01E20C02-01E4-64. WIRING4.4.4 DC Power ConnectionWhen using DC power as the power supply for theconverter, give attention to the following points.

Página 5 - 1.4 ATEX Documentation

IM 01E20C02-01E4-74. WIRING4.4.6 Wiring the Remote Flowtubewith the AXFA14 ConverterWARNINGBefore wiring, be sure that the power supply forAXFA14 con

Página 6 - 1. INTRODUCTION

IM 01E20C02-01E4-84. WIRING䊉 Pulse OutputIMPORTANT• As this is a transistor contact (insulated type),give attention to proper voltage and polaritywhe

Página 7 - 4. WIRING

IM 01E20C02-01E4-94. WIRINGThis output cannot switch an AC load. To switchan AC load, an intermediate relay must beinserted as shown in Figure 4.4.11

Página 8 - 4.2 Cables

IM 01E20C02-01E11. OUTLINEAccuracy (Combined with AXF Remote Flowtube)Pulse Output:PFA/Ceramics Lining:Size mm (in.)V  0.3 (1)1.0 mm/s0.5 mm/s0.5

Página 9 - 4.3 Wiring Ports

IM 01E20C02-01E11. OUTLINESafety Requirement Standards:EN61010-1EN61010-2-030• Altitude at installation site: Max. 2000 m above sea level• Installati

Página 10 - 4.4 Wiring Connections

IM 01E20C02-01E12. EXPLOSION PROTECTED TYPE INSTRUMENT(3) OperationWARNING• “OPEN CIRCUIT BEFORE REMOVING COV-ERS.”• “SEAL ALL CONDUITS WITHIN 18 INC

Página 11 - Power supply

IM 01E20C02-01E1. INTRODUCTIONIMPORTANTAn IMPORTANT sign denotes that attention isrequired to avoid damage to the instrument orsystem failure.NOTEA N

Página 12 - 4.4.5 Grounding

IM 01E20C02-01E1. INTRODUCTION(4) MaintenanceWARNING• Maintenance of the magnetic flowmeter shouldbe performed by the trained personnel havingknowled

Página 13 - 4. WIRING

IM 01E20C02-01E1. INTRODUCTION1.3 Combination RemoteFlowtubesIMPORTANT• The AXFA14 Magnetic Flowmeter Convertershould be used in combination with the

Página 14 - F0418.EPS

IM 01E20C02-01E1. INTRODUCTION1.4 ATEX DocumentationThis procedure is only applicable to the countries inEuropean Union.GBAll instruction manuals for

Página 15 - Cover locking

IM 01E20C02-01E1. INTRODUCTIONLTLVPLESTSLOHBGROMCZSK1-6

Página 16 - 11. OUTLINE

IM 01E20C02-01E4-14. WIRING4. WIRINGThis chapter describes the wiring on the converter sideonly. For information relating to wiring on theflowtube s

Página 17 - ■ MODEL AND SUFFIX CODE

IM 01E20C02-01E4-24. WIRING4.2 Cables(1) Dedicated Signal Cable (AXFC)Outer jacket 10.5 (0.413")Tape Shield (C) Insulation Insulation Shields (S

Página 18 - 12.3 CSA

IM 01E20C02-01E4-34. WIRINGOn the converter side85 (3.35)EX1EX2EX1EX285 (3.35)On the flowtube side Unit : mm(approx. inch)F0403.EPSCrimp Terminal Fig

Comentários a estes Manuais

Sem comentários