5
IM 77J01T21-01E 2nd Edition Feb. 09, 2007
11. LIST OF PARAMETERS
No. Item Display
01 Model MODEL
02 Tag No. TAG NO
03 Self-check result SELF CHK
Display items
A Display 1 DISPLAY1
A01 Input value INPUT1
A05 Output value 1 OUTPUT1 (*1)
A07 Alarm-1 status ALM1 STATUS
A08 Alarm-2 status ALM2 STATUS
A54 Status STATUS (*2)
A56 Rev No. REV NO
A58 Menu Rev MENU REV
A60 Self-check result SELF CHK
Setting items (*3)
D Setting (I/O) SET(I/O)
D01 Tag no.1 TAG NO.1
D02 Tag no.2 TAG NO.2
D03 Comment 1 COMMENT1
D04 Comment 2 COMMENT2
D07 Input sensor type SENSOR TYPE (*1)
D08 Thermocouple type TC TYPE
D15 Unit UNIT
D17 Input hard range selection SELECT RANGE
D22 Input low range INPUT1 L_ RANGE
D23 Input high range INPUT1 H_RANGE
D30 Burnout BURN OUT
D38 Direction of output-1 action OUT1 DR (*1)
D60 Self-check result SELF CHK
Adjusting items (*3)
P Adjustment ADJUST1
P01 Wiring resistance correction WIRING R
P02 Zero adjustment of input 1 ZERO ADJ1
P03 Span adjustment of input 1 SPAN ADJ1
P12 0% adjustment of output 1 OUT1 0% (*1)
P13 100% adjustment of output 1 OUT1 100% (*1)
P60 Self-check result SELF CHK
No. Item Display
B Display 2 DISPLAY2
B01 Input value INPUT1
B05 Output value 1 OUTPUT1 (*1)
B07 Alarm-1 status ALM1 STATUS
B08 Alarm-2 status ALM2 STATUS
B60 Self-check result SELF CHK
E Setting (alarm output) SET(ALM)
E01 Alarm-1 setting SET POINT1
E02 Alarm-2 setting SET POINT2
E05 Direction of alarm-1 action ALM1 ACTION
E06 Direction of alarm-2 action ALM2 ACTION
E07 Alarm-1 hysteresis HYSTERESIS1
E08 Alarm-2 hysteresis HYSTERESIS2
E11 Alarm-1 ON delay setting ON DELAY1
E12 Alarm-2 ON delay setting ON DELAY2
E13 Alarm-1 OFF delay setting OFF DELAY1
E14 Alarm-2 OFF delay setting OFF DELAY2
E15 Direction of alarm-1 relay action RL1 ACTION
E16 Direction of alarm-2 relay action RL2 ACTION
E60 Self-check result SELF CHK
Test items (*3)
Q Test TEST
Q01 ON/OFF of RJC RJC
Q02 Forced output 1 OUT1 TEST (*1)
Q04 Forced output (alarm 1) ALM1 TEST
Q05 Forced output (alarm 2) ALM2 TEST
Q60 Self-check result SELF CHK
*1 : The indications and settings of the parameters are not available.
*2 : The status is displayed for service personnel to see history records.
*3 : To call the parameter setting items D, E, P and Q using the JHT200 Handy Terminal, execute the following operation:
F1
ENTER
keys
D, E, P or Q key enters above.
Press
IMPOORTANT
Do not change the settings of the items marked “(*1)” in the List of Parameters above after the delivery of the prod-
uct. Doing so may result in a malfunction or a system failure.