OperationGuideYokogawa Electric CorporationModels 436101/436102/436103/436104/436106µR10000 RecorderIM 04P01B01-02E5th Edition
10IM 04P01B01-02E Names of PartsFront DoorName plateThe model name is writtenon the name plate.Power switchTurns ON/OFF the power each time the swit
11IM 04P01B01-02E Display and Key Panel RCDMENU FEEDCH UPFUNCMENUDISP1CHARACTERRECORD MATH CHART END ALARM1 2 3 4 5 6KEY LOCKESC/? SHIFTMa
12IM 04P01B01-02E Installing/Wiring the RecorderInstallation LocationInstall the recorder indoors in a location that meets the following conditions.•
13IM 04P01B01-02E • The proper torque for tightening the mounting screws is 0.7 to 0.9 N•m.• Mount the recorder to the panel according to the proced
14IM 04P01B01-02E Panel Cutout+20+20+20L+20L+20L (mm)2 2824265707148581002114612901434(144xn)-6345678910n137(5.39)137(5.39)+20137(5.39)137(5.39)Units1
15IM 04P01B01-02E Input Signal Wiring WARNING• To prevent electric shock while wiring, ensure that the power supply source is turned OFF.CAUTION• T
16IM 04P01B01-02E Wiring ProcedureA terminal cover is screwed in place on the measuring input terminal block on the rear panel.A label indicating the
17IM 04P01B01-02E Optional Terminal Wiring WARNING• To prevent electric shock while wiring, ensure that the power supply source is turned OFF.• If
18IM 04P01B01-02E NO C NCNO C NCNO C NCNO C NC/A2NO C NCNO C NCNO C NCNO C NCNO C NCNO C NC/A2/F1 /A2/R1I01I02I03I04I01I02I03I04I01I02I03I04CEFAILNO C
19IM 04P01B01-02E Power Supply Wiring WARNINGPanel Mount Type• To prevent electric shock when wiring, ensure the main power supply is turned OFF.•
PRS 108-02EUser RegistrationThank you for purchasing YOKOGAWA products.We invite you to register your products in order to receive the most up to date
20IM 04P01B01-02E Wiring Procedure (Panel Mount Type)The power supply terminals and protective ground terminals are located on the rear panel.1. Turn
21IM 04P01B01-02E Common Operations and Menu StructureExecution ModesThe recorder has three execution modes.Operation ModeThis mode is used for normal
22IM 04P01B01-02E Key OperationEntering Setting ModeHold down the MENU key for 3 seconds.The Setting mode display appears. The top and bottom lines ar
23IM 04P01B01-02E Changing the SettingsNoteThe comment line shows useful information such as a description of the setup item and the range of selectab
24IM 04P01B01-02E The character type changes each time you press the CHARACTER (MENU) key. The character type changes in reverse order each time you p
25IM 04P01B01-02E Menu Structure of Setting ModeReferences to the µR10000 Recorder User’s Manual (IM 04P01B01-01E) are given in parentheses.ClockAuxZo
26IM 04P01B01-02E Menu Structure of Basic Setting ModeReferences to the µR10000 Recorder User’s Manual (IM 04P01B01-01E) are given in parentheses.Add
27IM 04P01B01-02E Preparing to RecordLoading or Replacing the Chart PaperCAUTION• Do not install or remove the chart cassette with the chart paper gu
28IM 04P01B01-02E 4. Load the chart paper.Rife the chart thoroughly before loading. Make sure that the sprocket teeth of the chart drives are proper
29IM 04P01B01-02E Installing/Replacing Felt Pens (Pen Model)CAUTION• Do not press or pinch the felt tip to prevent deformation.• Do not move the penh
3IM 04P01B01-02E For detailed explanation of functions and the operating procedures of the recorder, see the µR10000 Recorder User’s Manual (IM 04P01B
30IM 04P01B01-02E Installing/Replacing the Plotter Pen (Pen Model)1. Open the door.If recording is in progress, press the RCD key to stop the recordi
31IM 04P01B01-02E 6. Remove the ribbon cassette.Pull the left-hand part of the ribbon cassette so that the cassette holder tab disen-gages, and pull
32IM 04P01B01-02E Checking or Setting the Date/TimeChecking the Date/TimeThe date/time is shown on the display when the DISP key is pressed several ti
33IM 04P01B01-02E Setting the Input Range and Alarm on Measurement ChannelsSetup Example (1) of Thermocouple InputSet channel 02 to thermocouple type
34IM 04P01B01-02E Setting Span Right8. Likewise, set Span_R to 450.0 and press the key. Span_R= 450.0-200.0/ 1370.0°CThe Setting complete s
35IM 04P01B01-02E Selecting the Input Type5. Press the key to select 1-5V and then press the key (see “Explanation” on page 38). Mode=1-5
36IM 04P01B01-02E Selecting the Unit16. Use the CHARACTER key and key to set unit character and then press the key. (For the procedure, see “Enter
37IM 04P01B01-02E Selecting the Input Type5. Press the key to select Scale, and press the key (for the selectable settings, see “Explanation” on
38IM 04P01B01-02E ExplanationNoteIf the range is changed after setting the alarm, the alarm setting becomes invalid. When you change the range, check
39IM 04P01B01-02E Setting the AlarmSetup ExampleSet a high limit alarm at 400.0°C on channel 02. The relay output (option) is not available.Entering S
4IM 04P01B01-02E Thank you for purchasing the YOKOGAWA µR10000 Recorder.This manual describes concisely the operating procedures of the µR10000 Record
40IM 04P01B01-02E Finishing the Settings10. When Setting complete screen is displayed, do either of the following:Press the key to set other alarms.T
41IM 04P01B01-02E Recording/Displaying DataStarting the RecordingPress the RCD key to start recording.The status display shows the word “RECORD.”NoteF
42IM 04P01B01-02E Changing the Chart Speed1. Hold down the MENU key for 3 seconds to enter Setting mode.2. Press the key to show Chart and then pr
43IM 04P01B01-02E Description of the Printout ContentsPrintout Description Figure (Pen Model) Nov.09.04!13:50*1 218.7mg/cm32 390.6
44IM 04P01B01-02E The printout description figures are for explaining the printout contents. The font is different from the actual printout. The print
45IM 04P01B01-02E Switching the Display ScreenThe screen switches each time the DISP key is pressed. Screen 01 through 15 are switched in order. Scree
46IM 04P01B01-02E Changing the Displayed InformationDifferent display types can be registered to screens 01 to 15. As an example, the procedure of ass
47IM 04P01B01-02E FUNC Key Operations in Operation ModeThe operations below can be carried out with the FUNC key in Operation mode. References to the
48IM 04P01B01-02E Aborting the Manual Printout1. Press the FUNC key.2. Press the key to select Print out and then press the key.3. Press the
49IM 04P01B01-02E Clearing the Alarm Printout BufferAlarm information waiting to be printed is temporarily stored in the buffer memory. This operation
5IM 04P01B01-02E WARNING• Use the Correct Power SupplyEnsure that the source voltage matches the voltage of the power supply before turning ON the po
50IM 04P01B01-02E Releasing the Alarm Output (Alarm ACK Operation)This operation releases the alarm indication or relay output (/A1, /A2, or /A3 optio
51IM 04P01B01-02E Setup Items and Default ValuesSetup Items in Setting Mode and Their Default Values (Recorder version: 1.31)The items with an asteris
52IM 04P01B01-02E Setup Item Pen/Dot Selectable Range or Selections Default ValueAux > DST - Not/Use NotAux > DST > Start month - Apr/May/Jun
53IM 04P01B01-02E Setup Items in Basic Setting Mode and Their Default Values (Recorder version: 1.31)Setup Item Pen/Dot Selectable Range or Selections
54IM 04P01B01-02E Setup Item Pen/Dot Selectable Range or Selections Default ValuePersonalize > Add function > Bias - Not/Use NotPersonalize >
55IM 04P01B01-02E Setup Item Pen/Dot Selectable Range or Selections Default ValueEthernet > DNS > S - IP address (Secondary DNS sever) 0.0.0.0Et
56IM 04P01B01-02E Recommended Replacement Periods for Worn PartsTo preserve the reliability of the recorder and to use the recorder in good condition
6IM 04P01B01-02E Checking the Contents of the PackageUnpack the box and check the contents before operating the instru-ment. If some of the contents a
7IM 04P01B01-02E Optional Accessories (Sold Separately)The optional accessories below are available for purchase sepa-rately. If you make an order,
8IM 04P01B01-02E Recorder’s Version and Functions Described in This ManualThe contents of this manual corresponds to the recorder with version 1.31.
9IM 04P01B01-02E Function Introduction/Names of PartsFunction IntroductionThe µR10000 Recorder (hereafter referred to as the recorder) can be used to