Yokogawa DA100 Manual do Utilizador Página 2

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 6
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 1
IM DA100-01E-88 2/6
for IM DA100-01E 8th Edition
Main Unit Type Name Model Q'ty
DA100-E 10-channel universal input module DU100-11 1
Ethernet module DT300-41 1
DA100-F 20-channel universal input module DU100-21 1
Ethernet module DT300-41 1
DA100-G 30-channel universal input module DU100-31 1
Ethernet module DT300-41 1
DA100-Q 10-channel universal input module DU100-11 1
RS-422-A/RS-485 module DT300-31 1
DA100-R 20-channel universal input module DU100-21 1
RS-422-A/RS-485 module DT300-31 1
DA100-T 30-channel universal input module DU100-31 1
RS-422-A/RS-485 module DT300-31 1
Note
When DA100-B, -C, -D, -E, -F, -G, -Q, -R, and -T are used while bought, the system need not be restructured.
However, when the position where the module is installed is changed or another module is installed, it is necessary to
restructure the system.
Page 6 “Optional Accessories”
Name Model Description
·············· ·················· ············································
AC adapter DV500-001 2-pin inlet w/UL, CSA cable for DC100/DA100/DS400/DS600
DV500-002 2-pin inlet w/VDE cable for DC100/DA100/DS400/DS600
DV500-003 2-pin inlet w/AS cable for DC100/DA100/DS400/DS600
DV500-004 2-pin inlet w/BS cable for DC100/DA100/DS400/DS600
DV500-005 2-pin inlet w/GB cable (complies with the CCC) for DC100/DA100/DS400/DS600
Page 7 “Safety Precautions”
The following caution has been added.
CAUTION
This instrument is a Class A product. Operation of this instrument in a residential area may cause
radio interference, in which case the user is required to take appropriate measures to correct the
interference.
Page 1-11 “DAQ Software 32 (standard accessory)” and “DAQ Software 32 Plus (special
order)”
The following five OS environment are supported.
• Windows 95 • Windows 2000
• Windows 98 • Windows XP
• Windows NT 4.0
Page 2-3 “Installation Method”
Panel installation
Attach the unit to the 2 mm-thick metal plate using the 6 screws included (length : 16 mm) according to the
figure below.
Page 2-14 “WARNING”
············································································································
When 30 VAC or 60 VDC and more is applied to the output terminal of the alarm output module or the output
terminal of the DI/DO module, use double-insulated wires (withstand voltage performance: more than 2300
VAC) for those wires which apply 30 VAC or 60 VDC and more. All other wires can be basic-insulated
(withstand voltage performance: more than 1390 VAC). ··········································
To prevent fire, use signal wires having a temperature rating of 75°C or more.
Vista de página 1
1 2 3 4 5 6

Comentários a estes Manuais

Sem comentários