13-4
IM DR232-01E
13.4 Error Codes
If servicing is necessary, or if the recorder does not operate correctly even though the following
corrective actions have been taken, contact your nearest Sales representative. Addresses may be
found on the back cover of this manual.
Error Code Error Corrective Action
001 System error. Contact your nearest representaive.
002 Set data out of range. Set numeric data correctly.
003 Time set incorrectly. Set time correctly.
004 Channels set incorrectly. Set channels correctly.
005 Invalid setting function parameter. Set parameter correctly.
006 Invalid character string. Set character string correctly.
007 Invalid type of input for input module. Set the type of input correctly.
008 Invalid range setting for input module. Set range correctly.
009 Numeric values out of range. Set numeric values correctly.
011 Attempted to do manual, header, list or Install new chart paper.
setup list printout at the end of chart paper.
030 There may be a module that cannot be set Re-set ranges or channels with
in channels with continuous ranges. continuous ranges.
031 There may be an invalid module in channels Change channels in which
with continuous ranges. continuous ranges are set.
040 Reference channel number greater than Change the reference channel number.
that of the channel for interchannel
differential computations.
041 Skipped range in the reference channel for Change the range in the reference channel.
interchannel differential computations.
042 RPJC range in the reference channel for Change the range in the reference channel.
interchannel differential computations.
043 SCALE in range setting in the reference Change the range in the reference channel.
channel for interchannel differential
computations.
044 The reference channel for interchannel Change the reference channel number.
differential computations does not exist.
045 The left and right spans are identical. Change the scale setpoint.
046 The left and right scale values are identical. Change the scale setpoint value.
060 The alarm setting was made in the channel Change ranges.
where SKIP was set.
061 The alarm was set to a channel with ranges Change ranges.
where alarm setting cannot be set.
062 The alarm setpoint is out of range in a Set correct alarm setpoint.
channel with continuous ranges.
063 Relay number set incorrectly. Set relay number correctly.
080 Invalid character strings for group setting. Set character strings correctly.
081 Invalid channel in character string for group Set channel correctly.
setting.
083 Partial compaction set to a channel where Change ranges.
SKIP was set.
084 Partial compaction set to a channel in Change ranges.
which ranges cannot be partially compacted.
085 Partial compaction out of range in a channel Set correct partial compaction range.
with continuous ranges.
086 The left and right zones have the same values. Change zone set values.
087 The left zone is wider than the right zone. Change zone set values.
088 The left and right zones are less than 5 mm Change zone set values.
apart wide.
089 Copy channel setting error. Sets the correct channel.
090 Attempted to copy a message with the same Change copy source or destination.
source and destination number.
091 Illegal protocol for logic setting. Set correct protocol.
100 No equation option Not possible to make any computation
settings.
101 Invalid code in the equation Set the equation correctly.
102 Incorrect number of ( ) in the equation Set the correct number of ( ).
103 Syntax error Set the equation correctly.