2-22
IM 04L21B01-64EN
Trend
Display Update 2nd Interval
Enabled when [Trend Rate Switching] is turned [ON] under [Environment] - [Detail
Setting] in the [Basic Setting] tab. Select a rate from the list.
The selectable 2nd intervals are the same as those for Trend interval.
Direction
Set the display direction of the trends to [Horizontal], [Vertical], [Wide], or [Split].
Trend Clear
Settings Description
ON Clears the displayed waveform when the memory sampling is started.
OFF Does not clear the waveform when the memory sampling is started.
Message direction
Set the display direction of messages to [Horizontal] or [Vertical]. When the trend is
set to Vertical, the message direction is xed to [Horizontal].
Scale Digit
Select the [Normal] or [Fine].
Fine If the scale value is two-digit display, it can be changed to three digits. For
example, if the scale range is “49.0 to 51.0,” the scale values are displayed
using 3 digits as shown below.
Value Indicator
The current value is displayed as a mark or a bar graph.
Trend Line
Set the line width of the trend in dots (1 to 3).
Grid
Select the number of grids to be displayed in the waveform display area of the trend
display.
Settings Description
4 to 12 Displays a grid that divides the display width into 4 to 12 sections.
Auto Displays the same number of grids as the number of scale divisions of the
first assigned channel of the group.