6-19
IM DR231-11E
Commands
6
• Parameters p7 and p8 are set in the range from 1
to the last data number in the file.
• Channel numbers are recognized in the order of
input channel and channel for computation. If you
set 005 for the first channel and A10 for the last
channel, an ASCII conversion will be made in
input channel 005 to the last input channel as well
as channels A01 to A10 for computation.
• This command is not executable during
computation.
FV Stores setting data on a floppy disk.
Mode Operation mode
Setting FVp1<terminator>
p1 File name (up to eight characters)
Example Store the setting data with the file name SET1.
FVSET1
Comments • This command is effective only with an optional
floppy disk drive function.
• Setting data in the setup mode cannot be stored.
To store them, use a YV command.
• This command is not executable during
computation.
FL Reads the setting data from a floppy
disk.
Mode Operation mode
Setting FLp1 p2<terminator>
p1 Method of reading data:
DIRECT Starts reading data
immediately after sending an
FL command.
TRIG_1 to 3 Starts reading data at the same
time as an event occurrence in
event/action functions.
p2 File name
Example Read setting data with the file name SET1
immediately.
FLDIRECT, SET1
Comments • This command is effective only with an optional
floppy disk drive function.
• Setting data in the setup mode cannot be read. To
read them, use a YL command.
• If TRIG_1 to TRIG_3 are set to p1, event/action
functions need to set FLOPY:LD_TRG1 to 3 for
their actions.
• This command is not executable during
computation.
FE Deletes a file on a floppy disk of
setting data.
Mode Operation mode
Setting FEp1<terminator>
p1 File name
Example Delete the file SET2.
FESET2
Comments • This command is effective only with an optional
floppy disk drive function.
• A data file in the setup mode cannot be deleted.
To delete it, use a YE command.
YV Stores set data in the setup mode on
a floppy disk.
Mode Setup mode
Setting YVp1<terminator>
p1 File name (up to eight characters)
Example Store set data in the setup mode with the file name
SET1.
YVSET1
Comments • This command is effective only with an optional
floppy disk drive function.
YL Reads set data in the setup mode
from a floppy disk.
Mode Setup mode
Setting YLp1<terminator>
p1 File name (up to eight characters)
Example Read set data in the setup mode, which are on the
disk with the file name SET1.
YLSET1
Comments • This command is effective only with an optional
floppy disk drive function.
YE Deletes a file on a floppy disk(Setup
Mode).
Mode Setup mode
Setting YEp1<terminator>
p1 File name
Example Delete the file SET2.
YESET2
Comments • This command is effective only with an optional
floppy disk drive function.
BL Executes the initial balancing of the
strain input channel
Mode Operation mode
Setting BLp1, p2, p3<terminator>
p1 The first channel for executing the initial
balancing
p2 The last channel for executing the initial
balancing
p3 Select either initial balancing or initialization
EXEC: Execute initial balancing
INIT: Execute initialization
Example Execute initial balancing on subunit 0 and channels
01 to 08.
BL001, 008, EXEC
Comments • Channels other than strain input channels or
channels that are not connected within the
specified range are ignored.
• Initial balancing and initialization can not be
executed during a report.
• If initial balancing is executed, number-of-
channels worth of data are returned in the
following format.
S1 S2 CCC DDCrLf
S1: Data status 1
N: Normal
S: SKIP
S2: Data status 2
Space: Data in the middle
E: Data at the end
CCC: Channel number
DD: Result of the initial balancing
OK: Initial balancing succeeded
NG: Initial balancing failed
DF: Default values set
_: Skip module
DR Start/stop the report
Mode Operation mode
Setting DRp1<terminator>
p1 Start/stop the report
6.6 Control and Execution Command